Since 1977, SICES Srl designs and manufactures Electronic Devices and Electric Control Panels for the management of Gensets by any producer and brand.

Starting from the project up to the production and to the start-up of the plants, every process is performed by a qualified and skilled staff thanks to the high technical experience.

With technologic pioneering, SICES started developing the first micro-processed Control Devices in the early ‘80s, becoming one of the first players for the high standard in quality, reliability and innovation, both in the control and management of gensets.

SICES is a partner of several high-level companies, supporting the customer from the project to the star-up of the plant.

SICES also offers an electric plant service engineering for the domestic/industrial distribution.

SICES is also involved in various projects to improve the energetic efficiency through sustainable and green sources as necessary bases for a sustainable development process. Therefore, it has been working for years in the photovoltaic field, both civil and industrial, offering the best products in terms of profit and quality on the market.


Download e-catalog

SiCES ATS115

SiCES ATS115

“Automatic Transfer Switch” Multifunctional controller
Source A Voltage (mains or genset)
L1-N, L2-N, L3-N, L1-L2, L2-L3, L3-L1
True RMS measure.
Lx-N max. voltage < 300Vac cat. IV
Source B Voltage (mains or genset)
L1-N, L2-N, L3-N, L1-L2, L2-L3, L3-L1
True RMS measure.
Lx-N max. voltage < 300Vac cat. IV
A or B Currents or towards load
L1, L2, L3, N
True RMS measure.
Nominal max. current: /5Aand /1A
Overload measurable current : 4 x 5Aac (sinusoidal)
A or B Frequency
Resolution = 0.1 Hz
Accuracy = ± 50ppm, ±35ppm/°C (tipical)
Controller Battery Voltage
Resolution = 0.1V

Communication
N. 1 USB Port to set the controller by PC
ATS115
N.1 USB Port
N.1 Serial port RS232 Modbus RTU
N.1 Insulated serial port RS485 Modbus RTU
N.1 RJ45 Port as Ethernet interface TCP/IP
CANBUS J1939 Interface
Optional:
N. 1 RS232 Serial Port Modbus RTU
N. 1 Insulated RS485 Serial Port Modbus RTU
N. 1 Ethernet RJ45 Port Modbus TCP/IP
RS232/485/USB Converter
GSM/GPRS/GPS Modem (REWIND)
Direct management Modem PSTN/GSM, data call in case of alarm. Status and Commands via SMS.
Supervisor Software for Windows
ATS115 and ATS115 are multilingual devices. The available display languages are: English, Italian, French, Russian and Portuguese/Brazilian.


Download e-catalog

SiCES GC315

SiCES GC315

Generator Voltages:
L1-N, L2-N, L3-N, L1-L2, L2-L3, L3-L1
True RMS measure
Lx-N max. voltage < 230Vac cat. IV
High voltage pulse = 6kV 1.2/50 us
Max. measurable voltage = 25.000V (by external VT).
Generator Currents:
L1, L2, L3, N (*)
True RMS measure.
Nominal max. current: 5Aac
Overload measurable current : 4 x 5Aac (sinusoidal).
Max. nominal current = 6000A (by external CT) cat. III
(*) Neutral generator current as alternative to differential
protection or to be used for measure mains power.
Mains Voltage:
L1-N, L2-N, L3-N, L1-L2, L2-L3, L3-L1
True RMS measure.
Lx-N max. voltage < 300Vac cat. IV
High voltage pulse = 6kV 1.2/50 us
Max. measurable voltage = 25.000V (by external VT).
Generator and Mains Frequency meter:
Resolution = 0.1 Hz.
Accuracy = ±50ppm, ±35ppm/°C (typical)
Battery Voltmeter:
Resolution = 0.1V
Oil Pressure Gauge:
VDO 0-10 Bar, VDO 0-5 Bar, Veglia 0-8 Bar
(optional 0-10V input)
Water Thermometer:
VDO
(optional 0-10V input)
Fuel Level:
VDO, Veglia
Engine revolution counter:
By pick-up. Programmable teeth number.
Same input can be used by W signal.
Power and power factor measures are available as total measure and also for
each single phase.Maximum power and current reached values, are memorized
with date and time.
Additional measures available based on the Insulated and Auto-supplied CAN J1939 .


Download e-catalog


 
SiCES ATS115

SiCES GC400

“Genset Controller for Synchro/Parallel Applications”
Mains Voltage:
L1-N, L2-N, L3-N, L1-L2, L2-L3, L3-L1
True RMS measure.
Lx-N max. voltage < 300Vac cat. III
Option 100V available on demand

Generator Voltages:
L1-N, L2-N, L3-N, L1-L2, L2-L3, L3-L1
True RMS measure
Lx-N max. voltage < 300Vac cat. III
Option 100V available on demand

Generator Currents:
L1, L2, L3, N (*)
True RMS measure.
Nominal max. current: 5Aac
Overload measurable current : 4 x 5Aac (sinusoidal).
(*) Neutral generator current as alternative to differential
protection or to be used for measure mains power from
CT (Standard) or Tore (option)

Bus Reading:
L1-N, L2-N, L3-N, L1-L2, L2-L3, L3-L1
True RMS measure
Lx-N max. voltage < 300Vac cat. III
Generator and Mains Frequency meter:
Resolution = 0.1 Hz.
Accuracy = ±50ppm, ±35ppm/°C (typical)

Battery Voltmeter:
Resolution = 0.1V

Oil Pressure Gauge:
VDO 0-10 Bar, VDO 0-5 Bar, Veglia 0-8 Bar
(Settable curve based on sensors available)

Water or Oil Thermometer:
VDO, Veglia, BERU
(Settable curve based on sensors available)

Fuel Level:
VDO, Veglia
(Settable curve based on sensors available)

Engine revolution counter:
By pick-up. Programmable teeth number.
Same input can be used by W signal.
D+ for the measure of the voltage alternator battery
charger
Power and power factor measures are available as total
measure and also for each single phase.
Maximum power and current reached values, are
memorized with date and time.
Additional measures available based on the
Insulated and Auto-supplied CAN J1939.


Download e-catalog

SiCES GC500P-M

SiCES GC500P-M

“Genset controller for synchro/parallel applications”

Mains Voltages
L1-L2, L2-L3, L3-L1 True RMS measure.
Lx-N max. voltage < 300Vac cat. IV

Generator Voltages:
L1-L2, L2-L3, L3-L1, True RMS measure.
Lx-N max. voltage < 300Vac cat. IV

Generator Currents:
L1, L2, L3, N True RMS measure.

Nominal max. current: /5A and 1A
Overload measurable current: 4x 5Aac (sinusoidal, max. 3 s)
(*) Neutral generator current as alternative to ground fault
protection or to be used for measure mains power.

Battery Voltmeter:
Resolution = 0.1V

Oil Pressure Gauge:
VDO 0-10 Bar, VDO 0-5 Bar, Veglia 0-8 Bar or Settable curve
based on sensors available
Coolant Temperature sensors:
VDO, Veglia, BERU or Settable curve based on sensors
available

Fuel Level:
VDO, Veglia, Generic max. 380 ohm or Settable curve based
on sensors available

Engine revolution counter:
By W. Programmable frequency/revolution ratio.
Same input can be used for pick-up signal.
Additional measures available by J1939 bus.
Linear Synchronoscope for synchronizing operations.


Download e-catalog